Contingency and continuity planning policy
Identified Potential Risks
The following identified risks will trigger a potential contingency event, each event is independently risk assessed and will be managed in accordance with this policy.
Natural disaster
- Fire
- Flood
- Sudden cessation of trade
- Sale of company
- Hardware failure
- Software failure
- Malicious attack
- Data breach
- Litigation
- Data theft
Application continuity and security
Our hosting network has multiple redundancies and security procedures including, but not limited to;
- 24 x 7 x 365 Manned Security & Monitoring
- Smart Card access policies
- Internal and External CCTV systems
- Security breach alarms
- 24 x 7 environmental monitoring systems
- Constant evaluation and testing of all systems
- N+1 redundant Heating Ventilation Air Conditioning (HVAC) system
- Fully redundant air handling units provide constant fresh airflow
- Raychem Fluid Detection
- FM200 fire suppression equipment
- Dual independent power feeds, backed up by dual battery string Uninterrupted Power Supplies (UPS) systems (deployed as standard)
- 2 Megawatt diesel generators to protect services from any single power failure
- Diverse fibre routing via multiple carriers
- Truncated internal cable network
- ODF/DDF (Optical Distribution Frame/Digital Distribution Frame) bandwidth
- Cross Connection to a number of Tier 1 carriers
- Internal inventory systems track all cables, circuits and cross-connects
- Scalable architecture including multiple redundant core switches and routers
Current up time (99.6%) and SLA agreed uptime (99.4%)
Bug fix procedure and error reporting (minor to mission critical) and estimated recovery time for various scenario outages from minor to complete disaster recovery as a table :
The maximum duration of service interruption upon total failure will be 24-48 hours. In this time a new server will be provisioned using the most recent whole server backup, brought online, checked and the most recent database backup accessible applied.
We expect service level to be near to 100% once the total failure procedure is complete, with a 24 hour allowance for complete back-up roll back.
We expect completely normal service to be resumed within a further 24 hours after the total failure procedure has been completed.
Triggering the Contingency Plan
Predictable Events
In the case of predictable and knowable events, such as the sale of the company, the contingency plan will be enforced at a set date that will be adequately advertised and discussed with our clients.
Unpredictable Events
When the event is unpredictable the plan will be triggered immediately once the issue is identified.
Failover testing, Pen testing and frequency
Our applications are penetration tested after every major release point. Any issues are identified and rectified and the penetration tests repeated.
Backup and recovery strategies are tested monthly for effectiveness, reliability and integrity.
Timely access to components necessary to make use of data
In the event of the company no longer trading we will make available an open source version of the code as it stands at the last version update. A detailed technical specification of the requirements will accompany this to run the code. All user data will be available to download.
Minimize risk of loss
Database data loss is minimised by a combination of transactional and full backups. Transactional logs are taken every 15 minutes and a complete backup taken every day. In the event of data loss due to error or mis-configuration the database can be rolled back to the suitable transactional data point and the data repaired. In the event of total failure or server crash a new instance can be brought online with a maximum data loss of 24 hours.
Application code and content (uploads and other user data) is backed up in full each day to off-site storage. Centralised versioning software is used to maintain a full and complete back of the application code and all changes.
Updates and changes are developed on the beta branch of the application code and fully tested before being merged in to the release branch.
Data Encryption and protection against data theft
Physical servers are protected by secure access and are only accessible by authorised personal.
Strong password policies are enforced on all physical servers.
All default ports are closed and only essential public ports are opened. Database traffic is restricted to only authorised servers and are not publicly exposed.
Latest OS security patches are applied on release.
All database stored passwords are encrypted with individual SALTs.
We recommend all clients utilise SSL to encrypt user to server traffic and prevent man in the middle attacks.
All API access is encrypted via SSL.
Changes
If you require further support or a different service level agreement, please contact the team on info@teamkientic.co.uk.
This agreement can be updated on a customer basis with 2 weeks notice and the agreement of both parties.
Customers can opt out of any single update, but any opt out may have unforeseen impacts and TeamKinetic cannot be held responsible or liable for these. Any opt out is at the risk of the customer.
Leave a Reply